Free tool
Reinforcement quantity calculator
Bar counts, total length and mass for two-way slab and wall reinforcement, and for beams and columns with ligatures.
Concept and estimating tool. Check results and get a design by a qualified engineer for construction. Nothing you enter is stored or sent.
How it works
Mass per metre = π db2/4 x 7850 kg/m3, which reproduces the nominal masses in AS/NZS 4671 (for example N12 0.888 kg/m, N16 1.58 kg/m, N20 2.47 kg/m). Bar counts are spacing-based within the cover, and laps are added as a percentage of length.
Questions
Does this include wastage and offcuts?
Only the lap allowance entered. Add a separate allowance for cutting waste and chairs if your estimate needs it.
Can I use it for a bar bending schedule?
No. It gives quantities for estimating. A bar bending schedule needs bar marks, shapes and dimensions from the drawings.
Module assistant
Rebar quantity assistant
Type a question about this tool or the site work around it. Answers come from 20 questions written and checked by a Chartered Professional Engineer. No AI, nothing is sent or stored.
Top 20 questions
What does the rebar quantity calculator work out?
It calculates the length and mass of reinforcing steel for bars, mesh, member bars and ligatures using AS/NZS 4671 N bar sizes. Use it for estimating and checking a bar bending schedule. It gives quantities only, and does not design the reinforcement or check detailing.
How is the mass per metre of a bar calculated?
Mass per metre is pi x d squared / 4 x 7850, with d in metres, giving kg/m. An N12 bar is about 0.888 kg/m and an N16 bar is about 1.58 kg/m. The calculator does this for each bar size, so you only need to enter the diameter and length.
What do N bars and the grade mean?
N bars are deformed reinforcing bars of normal ductility class in AS/NZS 4671 Steel reinforcing materials, with a nominal yield strength of 500 MPa. The number is the diameter in mm, so N16 is 16 mm. Check the drawings for the required bar type and ductility, and keep the supplier's test certificates.
How is mesh quantity calculated?
The calculator works out bars in two directions, so the number in each direction is member length divided by spacing plus one, and the total length is that number x the bar length. Convert the total length to mass using the bar size. If you are ordering standard mesh sheets, use the sheet area and the supplier's data.
How are member bars and ligatures calculated?
Member bars are the number of bars x the cut length. Ligatures (ties or stirrups) are the member length divided by ligature spacing plus one, x the ligature perimeter plus hooks. Check the drawings for hook lengths and spacing changes near supports, as ligatures are closer at the ends.
Are laps included automatically?
No. The calculator does not automatically add lap lengths, hooks, bends or wastage unless you enter them. Lap length depends on bar size, concrete strength and detailing in AS 3600, so take it from the drawings or the engineer. Add laps by increasing the bar length, or add a separate allowance.
What wastage allowance should I add to rebar?
Typical allowances range from a few percent to around 10 percent depending on cutting waste, offcuts and complexity, but there is no fixed figure. Use your own records or supplier advice. A fabricated and delivered bar schedule lowers waste because the supplier cuts to length, so check the order basis.
How do I convert mass to tonnes and order stock lengths?
Divide kilograms by 1000 to get tonnes. Reinforcing is usually supplied in stock lengths, commonly 12 m, or cut and bent to a schedule, but check what the supplier provides. For stock bar, plan cuts to minimise offcuts. For fabricated bar, issue the bar bending schedule and confirm the shapes and dimensions.
What is a bar bending schedule and who prepares it?
A bar bending schedule lists each bar mark, size, shape, dimensions, number and length for fabrication. It is normally prepared by a detailer or the reinforcement supplier from the engineer's drawings. Check it against the drawings before fabrication, since mistakes in the schedule are expensive to fix after delivery.
What cover is required and how do I maintain it?
Cover depends on the exposure classification and concrete strength in AS 3600 Concrete structures, and is shown on the drawings. Maintain it using spacers or chairs of the right size and spacing, tied to the bars, and check the cover before the pour. Insufficient cover leads to early corrosion.
What should be checked in a pre-pour reinforcement inspection?
Check bar size, spacing, number, laps, cover, ties, starter bars, hooks and the position of penetrations against the drawings. Confirm the steel is clean, free from loose rust or oil, and tied rigidly so it will not move during the pour. Sign the inspection record and fix defects before concrete is ordered.
Can I change bar sizes or spacing on site?
Not without the engineer's approval. A different size or spacing changes the area of steel, congestion and the concrete placement. If the specified bars are not available, ask the engineer for an equivalent and record the approval. Do not cut or move bars to fit services without a written instruction.
How should reinforcement be stored and handled?
Store off the ground on timber bearers, keep it clean and sorted by mark, and protect it from contamination. Use mechanical handling where possible to avoid manual handling injuries. Surface rust that is light and tight is normally acceptable, but loose scale, oil or mud must be removed. Follow the specification.
Is welding or heating bars allowed?
Only if permitted by the specification and carried out to a qualified procedure. Welding or heating can reduce strength and ductility in some bars, so do not weld reinforcing on site without approval. Never straighten or re-bend partly bent bars without checking the allowable bend diameter and the engineer's guidance.
What testing and certification applies to reinforcing steel?
Reinforcing steel should comply with AS/NZS 4671 and be supplied with test certificates or evidence of compliance traceable to the delivered batch. Keep the delivery dockets and certificates in the quality records. If the product is questionable, such as unmarked bar, raise it with the engineer before using it.
What are the safety risks with reinforcement?
Main risks are impalement on exposed bar ends, manual handling, cuts, falls and unstable bar stacks or mats. Fit protective caps to vertical bars, use walkways over mats, and plan lifting. The WHS framework expects these risks to be controlled in a safe work method statement. Do not leave uncapped starter bars.
How does congestion affect concreting?
Dense reinforcement at beam column joints and laps can block aggregate and vibrators, causing honeycombing. Check bar spacing against the maximum aggregate size and the vibrator diameter before the pour. If bars clash, raise it with the engineer early, and do not remove bars to make placing easier.
Are the results suitable for ordering without a schedule?
Not for fabrication. The calculator gives a quick estimate of length and mass for budgeting and checking, but orders for cut and bent steel need a full bar bending schedule from the drawings. Use the result to cross-check the schedule, since large differences can show an error in either.
When should I get an engineer to check reinforcement?
Get an engineer when the drawings are unclear, the bars do not fit, a substitution is needed, laps or cover are in doubt, or the work is for a critical element such as a transfer beam or retaining wall. Also call if inspection finds defects. EcoDesign can prepare a certified design.
How do I take off rebar for a slab or footing?
Work out bars in each direction as length divided by spacing plus one, then multiply by the cut length, which is the span less cover at each end plus any hooks or laps. Add top and bottom layers separately, and extra bars at edges or openings. Then convert the total length to kg using the bar mass per metre.
More free tools
Need this designed and certified?
EcoDesign Consulting prepares temporary works and structural designs signed by a Chartered Professional Engineer.