EcoDesign Consulting

Free tool

Active and passive earth pressure calculator

Rankine and Coulomb coefficients, the active pressure diagram and the resultant thrust for retaining walls, excavation support and temporary works.

Concept and estimating tool. Check results and get a design by a qualified engineer for construction. Nothing you enter is stored or sent.

How it works

Rankine coefficients for a vertical wall with level backfill:

Ka = (1 - sin φ) / (1 + sin φ)    Kp = (1 + sin φ) / (1 - sin φ)

The Coulomb option includes wall friction δ, backfill slope β and the back face angle θ. Active pressure at depth z is Ka(σ'v + q) - 2c√Ka, plus water pressure below the groundwater level. Negative values in cohesive soil are set to zero (tension crack). The thrust is the area of the pressure diagram.

Questions

Which method should I use?

Rankine suits vertical, smooth walls with level backfill. Coulomb accounts for wall friction and sloping backfill and gives lower active pressures where wall friction is reliable.

Is the passive value safe to use directly?

Passive resistance needs large movement to mobilise and should be reduced with a factor or a mobilisation ratio. Coulomb passive values with high wall friction are unconservative.

Module assistant

Earth pressure assistant

Type a question about this tool or the site work around it. Answers come from 20 questions written and checked by a Chartered Professional Engineer. No AI, nothing is sent or stored.

Try:

Top 20 questions

What does the earth pressure calculator work out?

It calculates active and passive earth pressure coefficients (Ka and Kp) by the Rankine or Coulomb method, then the pressure diagram, total thrust and the height at which the thrust acts above the base. It includes surcharge, cohesion with a tension crack, and groundwater. Use it for retaining walls, basements and shoring checks.

What inputs do I need?

You need wall height, soil unit weight, friction angle phi, cohesion c if any, surcharge q, groundwater depth, and for Coulomb the wall friction and backfill slope. Take soil parameters from the geotechnical report, not from typical tables, because friction angle and unit weight drive the result strongly.

Should I use Rankine or Coulomb?

Use Rankine for a smooth vertical wall with level or uniformly sloping backfill, which is the simple conservative choice. Use Coulomb when wall friction and wall batter matter, as it allows friction between soil and wall. Coulomb usually gives lower active pressure and higher passive pressure, so check which assumption your geotechnical engineer wants.

What is the difference between active, passive and at-rest pressure?

Active pressure occurs when the wall moves away from the soil enough to mobilise strength, and it is the lowest value. Passive occurs when the wall pushes into the soil and is the highest. At-rest pressure applies when the wall cannot move, such as a propped basement wall, and sits between them. The calculator gives active and passive.

How is surcharge included?

A uniform surcharge q adds a constant lateral pressure of Ka x q over the full height, which gives a rectangular block on top of the triangular soil pressure. Enter the real load behind the wall, such as stockpile, traffic or plant. Check the loading with the project specification and a qualified engineer.

How does the calculator handle cohesion and the tension crack?

Cohesion reduces active pressure by 2c sqrt(Ka). Near the top this gives negative values, so the soil is assumed to crack to a depth zc = 2c/(gamma sqrt Ka), and pressure there is taken as zero. Conservative practice ignores cohesion for long term design or where water can fill the crack.

How is groundwater included?

Below the water table the soil is taken at submerged weight (saturated weight less 9.81 kN/m3), and the full hydrostatic water pressure is added on top. Water pressure often dominates the wall load, so the total can rise sharply. Enter the groundwater level from the geotechnical report and consider seasonal highs.

What do the thrust and its height mean?

Thrust is the total horizontal force per metre length of wall, found by adding the areas of the pressure diagram. The height is the level above the base where that single force acts, found from the centroid of the diagram. Use both for overturning moment, sliding and bending checks of the wall.

What are the main limits of this calculator?

It assumes homogeneous soil layers, a vertical or simple wall geometry and fully mobilised active or passive state. It does not check stability, bearing, sliding, structural design or movement. Use it for preliminary sizing and checking. Final design needs a geotechnical engineer and a design under AS 4678 Earth-retaining structures.

Why does drainage behind a retaining wall matter?

Without drainage, water builds up behind the wall and adds hydrostatic pressure, which can double the load or more. Free draining backfill, a sub-soil drain with outlet, weepholes and filter fabric keep water out of the pressure diagram. Most failed retaining walls have blocked or missing drainage.

How should backfill be placed and compacted?

Place free draining granular backfill in thin layers and compact with light equipment near the wall. Heavy rollers close to the wall can create pressures higher than the design assumed. Follow the design for backfill type, layer thickness, and distance limits, and delay backfilling until concrete reaches the specified strength.

When is a temporary excavation support needed?

Support is needed when the excavation could collapse and endanger people, and any excavation deeper than 1.5 m generally triggers extra requirements under the WHS Regulations. Check the state rules, the geotechnical advice and the safe work method statement. Use battering, benching, shoring or trench shields, designed by a competent person for the soil and surcharges.

How do I allow for traffic, cranes and stockpiles near an excavation?

Include them as surcharge and keep the loads back from the edge. Cranes, trucks and spoil heaps increase lateral pressure and can collapse the wall or batter. Set an exclusion line, put the spoil back from the edge, and ask the designer for allowable surcharge by distance. Do not assume the design covers plant that was not specified.

Should I rely on passive resistance in front of a wall?

Be cautious. Passive resistance needs the wall to move to mobilise it, and soil in front may be removed later by services trenches, erosion or scour. Many designers reduce Kp with a factor of safety and ignore the upper layer. Confirm what the design allows, and do not excavate in front of the toe without approval.

What does a geotechnical report give me for the calculator?

It gives soil layers, unit weight, phi, cohesion, groundwater level and often recommended earth pressure coefficients and design parameters. Use the characteristic or design values stated and apply the load factors required by the design standard. If the report gives a range, test the sensitivity by running both ends.

Why are surface cracks or movement behind a wall a warning sign?

Cracks, settlement or a leaning wall indicate soil movement, higher pressure than assumed, or failure of drainage or support. Stop loading near the edge, keep people out of the zone, and get an engineer to inspect before work continues. Do not reload, backfill or dig more until the cause is known.

Does wet weather change earth pressure?

Yes. Rain raises groundwater, reduces soil strength and can fill tension cracks, so lateral pressure rises and stability falls. After heavy rain, inspect excavations and walls before work starts, pump out water, and check drainage outlets. Review the design if conditions are wetter than the geotechnical report assumed.

What safety and design framework applies to retaining walls and shoring?

The WHS Regulations require risk control and competent design for excavation and structural support. AS 4678 Earth-retaining structures covers the design of earth-retaining structures; temporary shoring is designed by a competent engineer to the project design basis. Keep records of design, inspections and changes, and make sure the work is done as designed. EcoDesign can prepare a certified design.

When should I get an engineer instead of relying on this tool?

Call an engineer for walls taller than about 1.5 m, any wall supporting a structure, road or neighbouring property, water or clay behind the wall, sloping ground, or unusual loads. The tool gives a quick estimate only. Final dimensions, drainage and stability checks need a qualified engineer using the geotechnical report.

How should I read the pressure diagram the calculator draws?

The diagram shows lateral pressure in kPa against depth, with the soil part as a triangle, the surcharge as a rectangle and any water as a separate triangle below the water table. The area under the diagram is the thrust per metre of wall. Check that the shape matches your site: a kink shows a layer or water level change.

Need this designed and certified?

EcoDesign Consulting prepares temporary works and structural designs signed by a Chartered Professional Engineer.

Get in touch